Most of a restaurant's water is used in the kitchen. Here is which machines draw it, how to estimate each one, and where the quickest savings are.

Cook using a pre-rinse spray valve at the dish pit of a commercial restaurant kitchen
In a restaurant kitchen, a few machines — the dish machine, the spray valve and the ice maker — account for most of the water.

The kitchen typically accounts for nearly half of a restaurant's total water use, according to the U.S. EPA. Inside the kitchen, the dish machine and the pre-rinse spray valve together account for more than two-thirds of the water in most commercial kitchens. There is no single “gallons per meal” figure that fits every restaurant, because menu, equipment age and staff habits move the number a lot. What you can do is learn which machines draw the water, and how to estimate each one.

Where a restaurant's water goes

Restaurants are among the more water-intensive commercial building types, and the kitchen is the main reason. Beyond the kitchen, water goes to restrooms, cleaning, and sometimes landscaping or cooling equipment. The kitchen share is the one owners can change fastest, because it is concentrated in a handful of machines.

Most of that kitchen water is also hot water. Dish rinsing and washing depend on heated water, so every gallon wasted carries a water charge, a sewer charge and the energy used to heat it. That is why efficiency work in kitchens pays back faster than the water bill alone suggests.

Which kitchen equipment uses the most water

Each major draw follows its own simple rule: flow rate times run time, gallons per rack times racks, or gallons per pound of ice. Here is how the main ones compare:

Main water draws in a commercial kitchen and what drives each one.
EquipmentWhat drives water useReference value
Pre-rinse spray valveFlow rate (gpm) × minutes in useNew valves limited to 1.00–1.28 gpm by class; older valves at 1.6 gpm or more
Commercial dishwasherGallons per rack × racks washedENERGY STAR listings show per-rack limits under one gallon, varying by machine type
Ice machineGallons per 100 lb of ice, plus condenser water if water-cooledENERGY STAR examples of about 13–20 gal per 100 lb (potable water)
Steam cooking equipmentContinuous water feed vs. self-contained steam generationCheck the manufacturer's rated gallons per hour
Sinks and floor washdownFaucet flow × run time; hose useVaries widely; metering is the only reliable way to know

The first two rows deserve the most attention, since they make up most of the kitchen total. The rest of the table is where hidden waste tends to sit: a machine nobody thinks about that runs all day.

Pre-rinse spray valves

The pre-rinse spray valve is the handheld sprayer at the dish pit that blasts food off plates before they go into the machine. EPA states that these valves can account for nearly one-third of the water used in a typical commercial kitchen, and that about one million U.S. food service establishments use nearly 53 billion gallons a year with them.

Federal rules now cap flow by spray force. Since January 2019, new valves must meet maximum flow rates of 1.00, 1.20 or 1.28 gpm depending on product class. Valves flowing at 1.6 gpm or more are the older, inefficient models EPA recommends replacing. Because these valves are cheap and the savings repeat every day, they are usually the best first upgrade.

Flow rate is only half the equation. A low-flow valve that is too weak to clean dishes just gets held on longer. Choose valves that meet the spray-force class you need, and train staff to scrape plates first and use the trigger only when water is needed rather than locking it on.

Commercial dishwashers

Commercial dish machines are rated in gallons per rack, and ENERGY STAR sets a maximum for each machine type: undercounter, door-type, single-tank conveyor and multiple-tank conveyor. In the certified-product listings those limits sit below one gallon per rack, though they differ by type, so compare a machine only against its own category.

Operation matters as much as the label. A machine run half-empty uses the same water per rack as a full one, which doubles the water per dish. Fill racks fully, scrape rather than rinse, keep final-rinse pressure and temperature within the manufacturer's range, and shut the machine off when service ends.

Ice machines and steam equipment

Ice machines use water in two ways: the water that becomes ice, and the water used to reject heat. ENERGY STAR-certified batch machines in the product finder list potable water use of roughly 13 to 20 gallons per 100 pounds of ice. A water-cooled machine adds condenser water on top of that, and models that send cooling water straight down the drain use substantially more than air-cooled ones. Ask for the machine's rated water use in both categories before you buy.

Steam-cooking equipment is the other quiet draw. Steamers, combi ovens and kettles can add substantially to a kitchen's total when water is fed continuously rather than generated inside the unit. Look up the rated gallons per hour on the spec sheet and ask whether a connectionless design is available.

Nearly half

~50%

The share of a restaurant's total water use that EPA attributes to the kitchen.

Spray valve limit

1.28 gpm

The highest flow rate allowed for a new pre-rinse spray valve; the lower classes cap at 1.00 and 1.20 gpm.

One valve swap

7,000+ gal

EPA's estimate of the yearly savings from replacing one old valve in a typical commercial kitchen.

Ice, per 100 lb

13–20 gal

Potable water use in a few ENERGY STAR-certified batch ice machine listings.

How to estimate your own kitchen's water use

Your water meter gives the total, but not the breakdown. To see which machine is responsible, estimate each one with its own rule, then compare the sum against the meter:

annual gallons = flow (gpm) × minutes per day × days open For a dish machine, use gallons per rack × racks per day × days open instead.

Here is an illustrative example. The run times and machine ratings below are assumptions chosen to show the arithmetic, not measured or published figures. Suppose a spray valve runs about 120 minutes a day over 360 days. At 1.6 gpm that is 1.6 × 120 × 360 ≈ 69,000 gallons a year; at 1.28 gpm it is about 55,000. The difference is roughly 13,800 gallons a year, before counting the hot-water energy saved.

For a dish machine, suppose 150 racks a day over 360 days. A hypothetical older machine at 1.2 gallons per rack would use about 64,800 gallons a year; one rated at 0.7 would use about 37,800. That is roughly 27,000 gallons a year saved. Replace the assumed numbers with your own rack counts and spec-sheet ratings, or use our water calculators for the surrounding math.

Practical ways to cut kitchen water use

Fix the high-flow valves first. Replace any pre-rinse spray valve flowing at 1.6 gpm or more, and test system pressure so the valve delivers the flow it was built for.

Scrape before you spray. Dry-scraping plates and pre-soaking heavily soiled pans cuts spray time, which is the variable you control.

Run full loads and shut things off. Full racks, auto-mode on conveyor machines and an end-of-day shutdown routine all reduce idle and partial-load waste.

Inspect for leaks and scale. A dripping valve or a scaled-up nozzle wastes water silently. Check them on a schedule.

Meter and track. Read the meter at open and close for a week. A rising overnight baseline usually means a leak or a machine left running.

The bottom line

Kitchens drive nearly half of a restaurant's water use, and the dish machine and pre-rinse spray valve make up most of that. Start with the cheapest fix, the spray valve, then compare your dishwasher and ice machine against their category ratings. Measure first, estimate each machine with flow × time or gallons per rack, and let the meter confirm where the water really goes.

Run the numbers Water Calculators Open →

Frequently asked questions

How much water does a restaurant use?

There is no single figure, because it depends on seating, menu, equipment and habits. EPA attributes nearly half of a restaurant's total water use to the kitchen, so the meter and a breakdown by machine tell you more than any average.

What uses the most water in a commercial kitchen?

In most commercial kitchens, the commercial dishwasher and the pre-rinse spray valve together account for more than two-thirds of the water use, according to EPA. Ice machines and steam equipment can add substantially on top.

How many gallons per minute should a pre-rinse spray valve use?

New valves sold in the United States are limited to 1.00, 1.20 or 1.28 gallons per minute depending on spray-force class. A valve flowing at 1.6 gpm or more is an older, inefficient model that EPA recommends replacing.

How much water does a commercial ice machine use?

It depends on the machine type. A few ENERGY STAR-certified batch machines list potable water use of about 13 to 20 gallons per 100 pounds of ice. Water-cooled machines use additional condenser water, and once-through cooling uses substantially more.

How do I compare commercial dishwashers on water use?

Compare gallons per rack within the same machine type. ENERGY STAR sets a maximum per-rack water use for each category, and the certified listings show limits below one gallon per rack. Running full racks matters as much as the rating.

How can I estimate my kitchen's water use?

Multiply flow rate by minutes in use and days open for spray valves and sinks, and gallons per rack by racks per day by days open for the dish machine. Add ice and steam equipment from their spec sheets, then compare the total with your water meter.

Sources & references

Figures in this guide come from these references. The worked examples are illustrative estimates, not published values:

  1. U.S. EPA WaterSense, Pre-Rinse Spray Valves. Spray valves as nearly one-third of kitchen water, the federal flow limits by product class, and the 7,000-gallon-a-year savings estimate.
  2. U.S. EPA WaterSense, WaterSense at Work: Introduction to Commercial Kitchen Equipment (archived snapshot). Kitchen share of restaurant water use and the dish machine and spray valve share of kitchen use.
  3. ENERGY STAR, Certified Commercial Dishwashers. Per-rack water limits by machine type.
  4. ENERGY STAR, Certified Commercial Ice Machines. Potable water use per 100 lb of ice for certified batch machines.
Sarah Bennett, MS
Sarah Bennett, MS

Water Quality & Sustainability Specialist · Portland, Oregon

Sarah writes Water Calculator's guides on water quality, treatment, usage and sustainability. Read full bio

MS · Specializes in water quality, treatment and water usage